{"id":186,"date":"2013-03-24T13:58:52","date_gmt":"2013-03-24T13:58:52","guid":{"rendered":"http:\/\/localhost\/wordpress-3.5.1\/wordpress\/?page_id=186"},"modified":"2013-04-12T12:37:48","modified_gmt":"2013-04-12T16:37:48","slug":"blast-chillers","status":"publish","type":"page","link":"https:\/\/veritay.com\/wordpress\/capabilities\/commercial\/temperature-controllers\/custom-designs\/blast-chillers\/","title":{"rendered":"Blast Chillers"},"content":{"rendered":"<p style=\"text-align: justify;\"><strong>Custom Blast Chiller Controller<\/strong> developed for a food-service equipment OEM to quickly cool or freeze food prepared in restaurants. The controller manages operation of the refrigeration compressor, defrost heater, and unit fan. Operating cycles are programmed via menu options displayed on the LCD graphics display unit. Features include:<\/p>\n<ul>\n<li>Automatic defrost cycle<\/li>\n<li>Large digit display of timed cycles<\/li>\n<li>Remote data logging to a PC<\/li>\n<li>Food probe verification<\/li>\n<li>Self diagnostics<\/li>\n<li>Password protection<\/li>\n<\/ul>\n<table id=\"table2\">\n<tbody>\n<tr>\n<td align=\"center\"><a href=\"http:\/\/wordpress.veritay.com\/wp-content\/uploads\/2013\/03\/controllerboard.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-570\" alt=\"controllerboard\" src=\"http:\/\/wordpress.veritay.com\/wp-content\/uploads\/2013\/03\/controllerboard.jpg\" width=\"128\" height=\"200\" srcset=\"https:\/\/veritay.com\/wordpress\/wp-content\/uploads\/2013\/03\/controllerboard.jpg 128w, https:\/\/veritay.com\/wordpress\/wp-content\/uploads\/2013\/03\/controllerboard-96x150.jpg 96w\" sizes=\"auto, (max-width: 128px) 100vw, 128px\" \/><\/a><\/td>\n<td align=\"center\"><a href=\"http:\/\/wordpress.veritay.com\/wp-content\/uploads\/2013\/03\/controllerboard2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter  wp-image-568\" alt=\"controllerboard2\" src=\"http:\/\/wordpress.veritay.com\/wp-content\/uploads\/2013\/03\/controllerboard2.jpg\" width=\"141\" height=\"216\" srcset=\"https:\/\/veritay.com\/wordpress\/wp-content\/uploads\/2013\/03\/controllerboard2.jpg 196w, https:\/\/veritay.com\/wordpress\/wp-content\/uploads\/2013\/03\/controllerboard2-98x150.jpg 98w\" sizes=\"auto, (max-width: 141px) 100vw, 141px\" \/><\/a><\/td>\n<td align=\"center\"><a href=\"http:\/\/wordpress.veritay.com\/wp-content\/uploads\/2013\/03\/controllerboard3.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-569\" alt=\"controllerboard3\" src=\"http:\/\/wordpress.veritay.com\/wp-content\/uploads\/2013\/03\/controllerboard3.jpg\" width=\"154\" height=\"200\" srcset=\"https:\/\/veritay.com\/wordpress\/wp-content\/uploads\/2013\/03\/controllerboard3.jpg 154w, https:\/\/veritay.com\/wordpress\/wp-content\/uploads\/2013\/03\/controllerboard3-115x150.jpg 115w\" sizes=\"auto, (max-width: 154px) 100vw, 154px\" \/><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: justify;\">A<strong> Retrofitted Blast Chiller Controller<\/strong> was developed as a direct replacement for an existing control system to provide the customer with additional features. The unit&#8217;s appearance remained unchanged, with stock overlay and integral printer still intact. The retrofit controller operates refrigeration compressor, defrost heater, and unit fan. A membrane keypad is used to manually set operating cycles and various system parameters. Key features include:<\/p>\n<ul>\n<li>Multi-segment display indicator<\/li>\n<li>Adjustable log and print interval<\/li>\n<li>Automatic or manual scan of food probes<\/li>\n<\/ul>\n<table id=\"table2\">\n<tbody>\n<tr>\n<td align=\"center\"><a href=\"http:\/\/wordpress.veritay.com\/wp-content\/uploads\/2013\/03\/controllerboard3.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-569\" alt=\"controllerboard3\" src=\"http:\/\/wordpress.veritay.com\/wp-content\/uploads\/2013\/03\/controllerboard3.jpg\" width=\"154\" height=\"200\" srcset=\"https:\/\/veritay.com\/wordpress\/wp-content\/uploads\/2013\/03\/controllerboard3.jpg 154w, https:\/\/veritay.com\/wordpress\/wp-content\/uploads\/2013\/03\/controllerboard3-115x150.jpg 115w\" sizes=\"auto, (max-width: 154px) 100vw, 154px\" \/><\/a><\/td>\n<td align=\"center\"><a href=\"http:\/\/wordpress.veritay.com\/wp-content\/uploads\/2013\/03\/rbcboard1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-581\" alt=\"rbcboard1\" src=\"http:\/\/wordpress.veritay.com\/wp-content\/uploads\/2013\/03\/rbcboard1.jpg\" width=\"169\" height=\"200\" srcset=\"https:\/\/veritay.com\/wordpress\/wp-content\/uploads\/2013\/03\/rbcboard1.jpg 169w, https:\/\/veritay.com\/wordpress\/wp-content\/uploads\/2013\/03\/rbcboard1-126x150.jpg 126w\" sizes=\"auto, (max-width: 169px) 100vw, 169px\" \/><\/a><\/td>\n<td align=\"center\"><a href=\"http:\/\/wordpress.veritay.com\/wp-content\/uploads\/2013\/03\/rbcboard2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-582\" alt=\"rbcboard2\" src=\"http:\/\/wordpress.veritay.com\/wp-content\/uploads\/2013\/03\/rbcboard2.jpg\" width=\"167\" height=\"200\" srcset=\"https:\/\/veritay.com\/wordpress\/wp-content\/uploads\/2013\/03\/rbcboard2.jpg 167w, https:\/\/veritay.com\/wordpress\/wp-content\/uploads\/2013\/03\/rbcboard2-125x150.jpg 125w\" sizes=\"auto, (max-width: 167px) 100vw, 167px\" \/><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Custom Blast Chiller Controller developed for a food-service equipment OEM to quickly cool or freeze food prepared in restaurants. The controller manages operation of the refrigeration compressor, defrost heater, and unit fan. Operating cycles are programmed via menu options displayed on the LCD graphics display unit. Features include: Automatic defrost \u2026 <a class=\"continue-reading-link\" href=\"https:\/\/veritay.com\/wordpress\/capabilities\/commercial\/temperature-controllers\/custom-designs\/blast-chillers\/\"> Continue reading <span class=\"meta-nav\">&rarr; <\/span><\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"parent":149,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-186","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/veritay.com\/wordpress\/wp-json\/wp\/v2\/pages\/186","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/veritay.com\/wordpress\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/veritay.com\/wordpress\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/veritay.com\/wordpress\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/veritay.com\/wordpress\/wp-json\/wp\/v2\/comments?post=186"}],"version-history":[{"count":3,"href":"https:\/\/veritay.com\/wordpress\/wp-json\/wp\/v2\/pages\/186\/revisions"}],"predecessor-version":[{"id":652,"href":"https:\/\/veritay.com\/wordpress\/wp-json\/wp\/v2\/pages\/186\/revisions\/652"}],"up":[{"embeddable":true,"href":"https:\/\/veritay.com\/wordpress\/wp-json\/wp\/v2\/pages\/149"}],"wp:attachment":[{"href":"https:\/\/veritay.com\/wordpress\/wp-json\/wp\/v2\/media?parent=186"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}